Pre-assembled boiler safety equipment group for sealed heating systems according to DIN EN 12828 with a capacity of up to 50 kW.
Consisting of: Carrier made of solid cast brass with G1 female boiler connection, approved safety valve ½” x ¾”, with PTFE seal ring, for flexible positioning - response pressure 3 bar, for capacities of up to 50 kW, ⅜” bottom connection, with mounting valve, air vent ⅜”, 12 bar, with mounting valve and preformed insulation.
• Time saving installation with pre-assembled,leak tested assembly.
• Service friendly – pressure gauge and air vent with self-sealing mounting valves, can be replaced without draining the system.
• Safe venting due to top mounted connection for air vent.
• Environmentally friendly – packing material is used as the insulation.